一区二区三区不卡在线观看,【乱子伦】国产精品www,国产人妖cd在线看网站,亚洲日日做天天做日日谢,色花堂国产精品首页第一页 ,国产欧美日韩在线不卡第一页,国产成人无码a区在线观看视频免费 ,FREECHINESE国产精品

      Barksdale Control Products 公司介紹

       
       
       
       
       
       
       
       
       
       
      應用領域
      郵件聯系我們
       

       

       

       

       

       

       

       

       

       

       

       

       

       

       

       


         

       

       

      Description

      Barksdale Intelligent Transmitters (BiT), Series 450E and H450E are BiT's Intrinsically Safe models. Barksdale has been manufacturing explosion proof transmitters for many years allowing their use in Class I Div 1 or Zone 0, 1 hazardous location. So why introduce an Intrinsically Safe (I.S.) model Explosion proof wiring requires metal conduit and special explosion proof sealing glands and junction boxes which are not practical for equipment that needs to be quickly rigged or broken down to modular sections to transport on roads to the next location such as Drilling, Frac or other mobile equipment. I.S. protection concept allows use in the same hazardous areas as explosion proof only with the same flexible cables and electrical connections used in ordinary locations including industrial and military style connectors used on our BiT 450 ordinary location models. Maintenance of systems is greatly simplified with quick electrical disconnects and no expensive explosion proof boxes that are susceptible to scratches on sealing flame path surfaces during maintenance. Barksdale's new intrinsically safe models also include advanced Thin-Film and HART technology providing all of the advantages of our other models including high accuracy and long term stability.

      Barksdale Intelligent Transmitters (BiT), Series 450E and H450E are BiT's Intrinsically Safe models.
      Series 450E BiT: Barksdale Intelligent Transmitters Instrinsically Safe Transmitter

       

      INSTALLATION VIDEO AND INSTRUCTION OPERATION VIDEOS:

      Click on the HART? communicator you are using to access the correct video.

      Emerson 475 Field Communicator
      Emerson AMS Device Manager
      DevCom2000 Device Communicator Installation
      Yokogawa Fieldmate Communicator Installation

       

      Features

      • Intrinsic safety certification with ATEX, IECEx and CSA approvals
      • Lightweight, compact and all-welded rugged stainless steel construction
      • High performance sensors
      • Optional HART? communication protocol with diagnostics & field calibration, reducing maintenance time and cost; 10:1 turndown ratio for re-ranging, maintaining high accuracy and allowing one part number for multiple pressure ranges
      • High accuracy: ±0.1% and 0.25% FSO, (L,H,R)
      • Additional CSA certification for ordinary locations
      • Factory sealed IP66 & IP67 and NEMA 4X enclosure
      • CE, NACE compliant and superior EMC/EMI protection
      • RoHS / REACH Compliant

       

      Technical specifications

      General Specifications*

      Accuracy (LH & R):
      at 75°F, Typical
      ±0.10% of Calibrated FSO (Option [–A1])
      ±0.25% of Calibrated FSO (Standard)
      ±0.50% of Calibrated FSO (Vacuum only
      [-23])
      Temperature Shift: Zero & Span: 0.0125% Per °F over the compensated temperature range
      Long Term
      Stability:closure rating:

      ±0.2% FSO /year of calibration curve
      Typical Life Cycle: 100 million cycles
      Proof Pressure: 2X range for up to 7,500 psi models
      1.5X range for 7,500 - 30,000 psi models
      Input: Excitation voltage: 9 to 30 VDC
      Supply Current: 20mA max.
      Output:
      H455E:



      455E:

      Output: 4–20 mA with HART? Protocol
      Full Scale Output: 20 mA ±1%
      Zero output: 4 mA ±1%

      Output: 4–20 mA
      Full Scale Output: 20 mA ±1%
      Zero output: 4 mA ± 1%
      Dynamic
      Response Time:
      Enclosure: All welded 300 series stainless steel. IP66 & IP67
      and NEMA 4X rated. 316 Stainless Steel (optional)
      Wetted Parts:
      Sensor:




      Fitting:

      17-4 PH Stainless steel (more than 10k psi)
      316L Stainless steel (up to 10k psi)
      Inconel (optional: up to 10k psi)
      17-4 PH Stainless steel for -UL option (10k psi)

      17-4 PH Stainless steel (all ranges)
      316L Stainless steel and 718 Inconel (optional: up to
      10k psi)
      Media
      General:

      Corrosive and Acidic:
      (up to 10,000 psi)

      Gas, vapor, liquid and viscous fluids [-Z17]

      718 Inconel wetted material, NACE [-NC], and 316L stainless steel, NACE [-SS]
      Pressure Connection:
      13 available options. Refer to product configurator
      for available connections and ranges.
      Electrical Connection: 10 available electrical connections such as M12, Bendix, DIN, conduit, gland and etc. Option for free leads from conduit or gland electrical connection includes two signal leads plus ground lead consisting of 18AWG halogen free type, 80” (2m) long or optional jacketed cable exiting 1/2 NPT or M20 conduit or gland connections.
      Temperature Ranges:
      Operating (Ambient):
      Compensated:
      Media:
      Storage:

      -40 to +176 °F (-40 to +80 °C)
      0 to +165 °F (-18 to +74 °C)
      -40 to +176 °F (-40 to +80 °C)
      -40 to +185 °F (-40 to +85 °C)
      Vibration: 10 g's, 10-500 Hz, MIL-STD 202, Method 204, Cond. A
      Shock: 50 g's, 11 mS, MIL-STD 202 Method 213, Cond. G.
      Approvals:
      CSA

      CSA









      ATEX/IECEx

      cCSAus Ordinary Locations

      cCSAus Intrinsic Safety for Hazardous Locations
      Class I, Div. 1, Groups A, B, C & D
      Class II, Div. 1, Groups E, F & G
      Ex ia IIC T4 Ga
      Ex ia IIIC T135°C Da
      Class 1 Zone 0, AEx ia IIC T4 Ga
      Zone 20 AEx ia IIIC T135°C Da

      Factory sealed IP66 & IP67 and NEMA 4X enclosure

      CE 0081
      Ex II 1 G D
      Ex ia IIC T4 Ga
      Ex ia IIIC T135°C Da, IP66 & IP67
      -40 °C ≤ Tamb ≤ +80 °C
      CML 19 ATEX 2240X
      IECEx CML 19.0066X
      HART? Protocol:

      Turndown Ratio:

      Analog Output
      Calibration:



      Sensor Trim:

      Diagnostics:
      HART? 7.6

      10:1 (Full scale output rangeability)


      Adjustable zero and span of 4-20mA.
      Full scale range must be ≥ (calibrated
      span / 10)

      Sensor zero and full scale trim

      Transmitter failure indicated by off-scale
      analog signals to alarm the user

      See HART Installation and Operation
      Manual 272438 for detailed information
      Compliances: CE,
      NACE (316L SS or 718 Inconel wetted material)
      Electromagnetic
      Capability (EMC)
      IEC/EN 55011:


      IEC/EN 61000-4-2:


      IEC/EN 61000-4-3:


      IEC/EN 61000-4-4:


      IEC/EN 61000-4-5:



      IEC/EN 61000-4-6:


      Emission & radiated emission for class A
      limits

      Electrostatic discharge (ESD) test - contact
      discharge +/-4 kV, Air discharge +/-8 kV

      Radiated RF, EM field immunity
      80mhz-1ghz, 3v/M

      EFT (Burst) Test, +/-2 kV


      Surge Test, +/-1kV on lines, +/-2kV between
      line and earth ground


      RF Immunity, 150 kHz – 80 MHz, 3V
      Weight: 16 Ounces (453 grams)
      Warranty: 1 year warranty
      Installation: Intrinsic Safety Installation for Hazardous Locations:
      Install per Barksdale Control Drawing 272471

       

      Series 450E BiT: Barksdale Intelligent Transmitters
      Instrinsically Safe Transmitter

      High accuracy pressure transmitter with HART? communicaton protocol with 24 standard ranges from vacuum to 30,000 psi


      Applications

      • Drilling rig control & monitoring instrumentation
      • Drilling and frac offshore equipment skids
      • Production control systems
      • Chemical injection systems
      • Oil & gas pipelines
      • Petrochemical plants
      • Refineries
      • Gas and oil fired power plants
      • Hydraulic power units
      • Gas transfers for fuel systems
      • O&G process pumps
      • Gas compressors
      • Generators and turbines

      INSTALLATION VIDEO AND INSTRUCTION OPERATION VIDEOS:

      Click on the HART? communicator you are using to access the correct video.

      Emerson 475 Field Communicator

      Emerson AMS Device Manager
      DevCom2000 Device Communicator Installation
      Yokogawa Fieldmate Communicator Installation


      Since 2007
         


      美國DMK Engineering Solutions公司
      信德邁科技(北京)有限公司 CNMEC Technology


      地址:北京市朝陽區望京街10號望京SOHO塔1C座2115室
      郵編:100102
      電話:010-8428 2935, 8428 3983
      手機:139 1096 2635
      Http://www.0591w.com
      E-mail:sales@cnmec.biz
      傳真:010-8428 8762


      京ICP備08000876號-1
      京公網安備 11010502019740
      Since 2007 Strong Distribution & Powerful Partnerships